LIFE WITHOUT A NEUTRAL CONDUCTOR IN A SUB – PANEL
Dec 23, 2024 · The detached garage sub-panel, which used to be the main panel, is properly grounded with number #6 copper and is connected to an outside ground rod. EXISTING LOADS: My detached garage has a small 240 V compressor, 4-120 V …
attached garage sub panel AND generator hookup?
Oct 8, 2024 · 2-2-2-4 aluminum for the 80A feeder to the sub-panel. It's rarely a wrong answer. The load in your main panel isn't decided by the sub-panel main, it's decided by the actual loads in the garage. 10/3 UF, or 6-6-6-6 aluminum for the generator feeder. The 6-6-6-6 is 44A and cheap. I already applied the adjustment for 2 circuits in 1 conduit.
Adding subpanel vs new larger panel - DIY Home Improvement …
Dec 13, 2010 · In my case, I had a 200A main panel that was full and I needed expansion space. I opted for a subpanel instead of a new main panel because of where the main panel is located (near an outside wall under a low slope attic, making it extremely difficult to pull wires from the attic into the panel).
Adding a Sub Panel for Transfer Switch - DIY Home Improvement …
Jun 3, 2009 · The sub panel will be controlled by a 100amp automatic transfer switch with a 20kw standby generator or a 100amp breaker from the main panel. To move the circuits to the sub I must splice the circuits with wire nuts in the main panel. Wires are not long enough or accessible to reroute them to the sub My question is: Is it OK to just move the ...
NEC Sub-Panel Placement - DIY Home Improvement Forum
Apr 13, 2013 · I pulled the permit to put in the 100 Amp sub-panel, in the garage, 70 feet from the 200 Amp main panel. I told the inspector I was planning on using copper 3 AWG for the 3 mains and an 8 AWG. He consulted with some of the other inspectors and produced an NEC table that said for a 100 Amp sub-panel, under 110 feet from the main, they only ...
Ading sub panel and wiring a garage work shop without...
Jan 11, 2025 · We will be adding a Square D Homeline panel to match the other panels in our home.Themain workshop is for wood working. I will need several 220/240 single phase out let (3 x 25amp, 1 x 15 amp and 1 x 45 amp leg) Ihave lighting (10 LED lamps powered from an another panel), but I need to wire these.
Sub Panel Question - DIY Home Improvement Forum
Sep 25, 2024 · The panel in the picture does show bonding of the neutral and ground; this should be your main panel then. Running a feeder to a sub panel would include four wires, 2 hots, ground and neutral; if using metal conduit the entire run from main to sub the conduit can act as the ground. Then the ground and neutral will be separate in the sub panel.
Sub panel wiring question - DIY Home Improvement Forum
Feb 24, 2009 · What I need to ask is that my sub panel, has 3 lugs, 2 H and 1 N & a Ground lug. So my sub panel has 3 3/8 lugs, 2 H and 1 N. The diagram has the N from my MAIN panel going to the ground in the sub, however that doesnt take into account my 3/8 N lug on my sub panel. Any help is appreciated!
New sub panel install - DIY Home Improvement Forum
Dec 3, 2024 · Ended up returning the QO panel, and installing a 100A 20-Space 40-Circuit Homeline panel with a main disconnect switch. I moved a 2-pole breaker from the main panel and installed a 100A breaker to power the new sub panel. I won't need to worry about the need for more space in the future. Question.
Sub Panel, Junction Boxes | DIY Home Improvement Forum
Dec 3, 2018 · I want to install a new electrical sub panel to our garage as the whole garage is served by one 15 amp circuit and that already pops when I run the air compressor. I'd like to run a 220 line in the garage and move all the existing outlets to the new sub panel. Do I only need to run one cable from the main box to the sub panel?